FAN SPEED
This humidifier is equipped with a 3-speed fan control. Initially
pressing the speed button will display the current speed setting.
Each push of the speed button advances the mode through the
settings of (HIGH) F3, (MEDIUM) F2 , (LOW) F1 and A (AUTO).
HUMIDITY CONTROL
This button allows you to adjust the humidity to suit your needs.
This humidifier will automatically cycle on and off as required to
maintain the selected setting.
The readout displays both actual (ROOM) and desired (SET)
humidity percentage (%) settings when humidity control button is pressed. The ROOM
readout has a range of 20% to 90% RH. If the room humidity level is equal to or less
than 20% the display will show a flashing 20. When above 90%, two bars (- -) will flash
on the display and the fan will stop.
The SET readout has a range of 25% to 65% RH and is adjusted in increments of 5%.
Initially depressing the humidity button will display the current humidity setting. Each
additional press of the button increases the setting by 5%. A SET point of 65% RH
operates the humidifier continuously until it reaches above 90%, at which time the fan
will turn off. The humidistat that senses the readings is located on the power cord.
Ensure that it is free from obstruction.
REFILL DISPLAY
For maximum run time both the bottle and the base should be filled.
When both the bottle and the base are empty, the display alternates
the room humidity reading and “F” (FILL), indicating additional
water is required.
CHECK FILTER INDICATOR
The ability of any humidifier to efficiently supply humidity output
relies heavily on the condition of the wick (filter). As the wick loads
with impurities it gradually loses its wicking capability. When this
happens, moisture output is reduced and the humidifier has to work
longer to satisfy the selected setting. This humidifier has a check
filter reminder timed to appear after 720 hours of operation. When the display shows
an alternating “CF” and “room humidity” setting at 5 second intervals it is a reminder
to check the filter (wick) condition.
NOTE: Some areas have high water mineral content causing the need for more
frequent wick changes.
Reset the Check Filter “CF” function each time you replace a wick by unplugging the
unit from the power source for 1-2 minutes, then plug it in again.
Refer to Replacement of Wick” section below. If a build-up of deposits or severe
discoloration is evident, replace the wick to restore maximum efficiency.
CONTROL LOCK FEATURE
To avoid unwanted tampering with the humidifier settings the
controls can be locked.
CONTROL LOCK ACTIVATION PROCEDURE
After the humidifier functions have been set up, hold the power
button down for 5 seconds. The display will show “CL” for 2 seconds; release the
power button and the control will resume the display of the room humidity. The
humidifier will continue to function with the locked in settings. If buttons are operated
while “CL” is active, the “CL” is displayed and settings are unaffected.