Troubleshooting
Trouble
Probable Cause
Remedy
Digital display not
illuminated.
• No Power.
• Power button has not been
depressed.
• Check 120 volt power source.
• Press power button once to
turn on.
Fan not operating (digital
display is illuminated).
ROOM humidity level is not 3%
or more below SET humidity
level.
• Reservoir is empty.
• Raise SET humidity level if desired.
• Increase fan speed.
• Fill humidifier with water.
Fan running continuously.
• Float is obstructed.
• SET humidity level is
65%.
• ROOM humidity level
has not reached 1% or
more above SET
humidity level.
Free float from obstruction.
• A SET humidity percentage of 65%
operates fan continuously. Adjust
SET level between 25% - 60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
Poor evaporation of water.
CHECK FILTER (CF) message
flashing.
• Mineral buildup on filter (wick).
• Change to a fresh new wick
NOTE: Local water varies from area
to area and under certain conditions
minerals will build up more rapidly in the
wick.
•Unplug unit for 1-2 minutes to reset
CF function
Neither bottle emptying. • Bottle cap plunger
missing post in bottom
of cabinet
• Dirty wicks.
• Check orientation of bottles.
Reposition so that bottle cap
plunger (stem) is depressed by
post in bottom of cabinet.
• Change to fresh new wick
(HDC12).
Bottles continue to empty
after complete filling.
• Air is entering water
bottle.
•Check “Side-Fill Caps” and valve
assembly caps to ensure tightness.
• Check for leak in water bottle.
Ensure gaskets for “Side Fill Caps”
are in place.
Left bottle not emptying. • Right bottle contains
water.
The humidifier is designed so that
right bottle empties first.
• Ensure unit is level - Install caster
pads on front casters, as needed.
Bottle empties completely
• This is normal for initial filling
• Refill bottle for maximum
run time.
Refill display “F” is on
before bottles are empty.
• Unit is not set up on a
level surface. (Float
will not sense water at
the front of the
cabinet.)
Position unit level. (Some carpet padding
may allow unit to sit lower in the front than
rear with the additional weight of water
bottles in the front of the cabinet. Install
caster pads under front casters.
“CF” message does not
appear even when wick is
dirty or humidifier
performance is clearly
reduced.
• Loss of power or a
power failure has caused the
CF message to prematurely
reset.
• Replace wick.
Display blinks or fan moves
slightly when humidifier is
plugged in.
Normal
• No action required.